Environment Monitoring Gas Detection Sensor

Carbon dioxide monoxide Hydrogen Methane
Butane Monitor Protect Warning Alarm, how to

Environment Monitoring System Gas Detectors

Gas Detection Sensors compatible with ENVIROMUX-16D

Gas Detection Sensors

Carbon Monoxide Detector, CO

ENVIROMUX-CMD Carbon Monoxide Detector, CO
ENVIROMUX-CMD
  • Continuous air monitoring.
  • Pre-set alarm points alert at:
    • 70 ppm after 60 to 240 minutes
    • 150 ppm after 10 to 50 minutes
    • 400 ppm after 4 to 15 minutes
  • Flush or surface mount.
  • Test functionality of electrochemical CO sensing cell.
  • Connect to RJ45 or digital input sensor ports.
  • Screw terminal
    • To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
    • Maximum cable length: 1000 ft (305m)
  • LED indicators for operation status and system test.
  • Powered by ENVIROMUX-2D/5D/16D.
  • Regulatory approvals: UL
Downloads & References


NTI Part # Quote
ENVIROMUX-CMD

Carbon Dioxide Sensor, CO2

ENVIROMUX-CO2 Carbon Dioxide Sensor, CO2
ENVIROMUX-CO2
  • CO2 room sensor for periodically unoccupied areas.
  • Measures CO2 in a range of 0 to 2,000 ppm.
  • 0 to 5 VDC output.
  • Continuous automatic air pressure compensation.
  • LED indicators for operation status and system test.
  • Requires the ENVIROMUX-S5VDC sensor converter to operate.
    • Maximum cable length: 1000 ft (305 m).
  • Includes 12V/1A power supply.
  • Regulatory approvals: RoHS
  • Compatible with ENVIROMUX-FSC Fiber Converter/Extender.
    • Use to extend sensor up to 1.2 miles (2 km) from the ENVIROMUX unit.
Downloads & References
NTI Part # Quote
ENVIROMUX-CO2
ENVIROMUX-S5VDC

Gas Detector — Methane, Butane, Propane

Gas Detector - Methane, Butane, Propane
ENVIROMUX-GD-MBP
  • Use to detect leaks of combustible gas (methane, propane, butane, acetylene, etc.)
  • Choose between two levels of detection:
    • First level:
      • Detects methane at concentrations in excess of 0.5%.
      • Detects propane/iso-butane at concentrations in excess of 0.3%.
    • Second level:
      • Detects methane at concentrations in excess of 0.8%.
      • Detects propane/iso-butane at concentrations in excess of 0.5%.
  • Continuous air monitoring.
  • Audible alarm signal: 94 dB at 1 foot.
  • Relay specifications: level selectable, normally open or normally closed, 250V AC, max 5A.
  • Maximum cable length: 1000 ft (305m)
  • Powered by ENVIROMUX-2D/5D/16D.
  • Regulatory approvals: CE
Downloads & References
NTI Part # Quote
ENVIROMUX-GD-MBP

Hydrogen Gas Detector

Hydrogen Gas Detector
ENVIROMUX-H2
  • Use to detect leaks of hydrogen gas in battery monitoring/charging rooms, substations, uninterruptible power supplies (UPS), and hydrogen fueled back-up power systems.
  • Alarm set point: 10% LEL hydrogen gas.
  • SPDT Alarm and normally-closed output relay.
  • Self-restoring or latching options.
  • Sensor requires no maintenance or recalibration.
  • Includes mounting hardware.
  • Voltage supply: 12 to 24 VDC or VAC.
  • Operating temperature: 32 to 120°F (0 to 49°C).
  • Dimensions WxDxH (in): 4.5x5x1.63 (114x127x41 mm).
  • Powered by ENVIROMUX-2D/5D/16D.
Downloads & References
NTI Part # Quote
ENVIROMUX-H2

Back to Top